Survey Equipment

Buckleys H23 - Marine Reference Cell

Follow us
  • Buckleys H23 - Marine Reference Cell
H23 Marine reference cell 25m cable data sheet
Find out more about this product Contact us

Description

The Marine Silver/Silver Chloride Half Cell is suitable for installation on surface structures such as jetties. It has been specially designed to allow easy monitoring when connected to a separate high impedance voltmeter (greater than 10 meg Ohm).  The electrode is housed in a PVC body with holes to allow the easy flow of water around the electrode. The Half Cell is supplied with 12.5 metres of CSP 55/015 cable. Other cables lengths can be supplied, if required, further details on request. The cell is long lasting and will give a service life of up to 5 years in ideal conditions.

Key features

Electrical connection: free end.

Output: +42mV @ 25°C to K-Series reference cell.

Accuracy: +/-10mV in 3% sea water.

Temperature coefficient: -0.6mV/°C.

Temperature range: 0-30°C.

Working life: 1 to 5 years.

Weight (cell & cable): 350g.

Size: 140mm long x 25mm diameter.

Packed weight: 0.65Kg.

Dimensions (packed): 26cm x 14cm x 30cm.